Canada Fluorspar Inc. (TSX VENTURE:CFI) ("CFI" or the "Company") is pleased to
announce assay results from four (4) holes on its Phase 2 diamond drilling
program along the southern extension of the Director Vein. The assay results
from the previous eleven (11) drill holes from the Company's Phase 1 and Phase 2
diamond drilling program were disclosed by press releases on March 12, 2013,
April 24, 2013, and May 8, 2013 and June 5, 2013.


All four drillholes, DS-13-110, DS-13-111, DS-13-112 and DS-13-136, are located
on the same cross-section at 1,500 metres south of the old Aluminum Company of
Canada ("Alcan") shaft and 223 metres north of the previously reported holes
from the June 5, 2013 press release. Hole DS-13-110, the shallow hole, was
collared with an azimuth of 050 degrees (GN) and an inclination of -60 degrees,
and intersected the Director Vein structure returning average assay values of
65.8% CaF2 over 3.17 metres from 44.23 metres to 47.40 metres measured depth.
Drill hole DS-13-111 was collared with an azimuth of 050 degrees (GN) and an
inclination of -65 degrees and intersected the Director Vein structure returning
average assay values of 91.3% CaF2 over 2.42 metres from 79.80 metres to 82.22
metres measured depth. Hole DS-13-112, the 3rd deepest hole in the plane, was
collared with an azimuth of 050 degrees (GN) and an inclination of -80 degrees
and intersected the Director Vein structure returning average assay values of
43.0% CaF2 over 2.95 metres from 135.77 metres to 138.72 metres measured depth.
Drillhole DS-13-136, drilled from east to west and the deepest of the four holes
in the plane, was collared with an azimuth of 228 degrees (GN) and an
inclination of -57 degrees and intersected the Director Vein structure returning
average assay values of 81.3% CaF2 over 0.70 metres from 207.80 metres to 208.50
metres measured depth and a second vein was intersected in the structure
returning average assays of 37.0% CaF2 over 6.16 metres from 216.50 metres to
224.66 metres measured depth, not including 0.30 metres of lost core in the
intersection.


"The assays from these four holes as well as previously reported holes,
DS-13-115, DS-13-116, DS-13-120, DS-13-121 and DS-13-122 are encouraging in that
the southern extension of the Director Vein in this area is now known to extend
from surface to a projected depth that range from 75 to 150 metres and along a
projected north-south strike over 320 metres with grades and widths that would
categorize the mineral resources as mineable," stated Lindsay E Gorrill,
President & CEO of Canada Fluorspar Inc.


The fluorite mineralization in the north-south trending veins at the St.
Lawrence Project and the Company's 100% owned mineral license occur in the form
of massive mineralization and as fault gouge. Historically, core drilling of the
massive mineralization has resulted in good core recovery. The areas of faulted
mineralization generally contain finely ground fluorite and larger fragments of
the harder siliceous material. Drilling through the faulted gouge zones commonly
results in poor core recovery as the fine grained fluorite material in the vein
is washed out by the drill fluid. Drill hole DS-13-136 successfully intersected
the Director Vein structure; however, due to the fine nature of some of the vein
material, core recovery in the structure was 95%. Past underground mine
operations document the high grade, fine, sandy fluorite mineralization in the
vein structure.


To view the associated map, please visit the following link:
http://media3.marketwire.com/docs/cdn-fluorspar-0702.jpg.


Assay Results

CFI has received assay results for samples collected from drill holes DS-13-110,
DS-13-111, DS-13-112 and DS-13-136 located along the southern extension of the
Director Vein. Three of the four drill holes (DS-13-110/111/112) were drilled
from west to east and located 100 metres south of a previously reported hole,
DS-13-116, which was reported in a press release dated May 8, 2013. Drill holes
DS-13-110, DS-13-111, DS-13-112 and DS-13-136 are located on the same plane and
were drilled to intersect the Director Vein structure below a previously
reported trench, Trench No. 2, which was reported in two press releases, dated
March 1, 2012 and April 16, 2012. Trench No. 2 was reported to have exposed
10.3% CaF2 over 3.4 m of gouge, and 13.3% CaF2 over 1.0 m of wall rock on the
west side of the vein. The combined grade over 4.4 m was 11.0% CaF2.


All four drill holes intersected the Director Vein structure, which trends
north-northwest and dips steeply from east to west. Drill hole DS-13-110
intersected the Director Vein structure at 41 metres vertically from surface and
below Trench No. 2. Drill hole DS-13-111, drilled below DS-13-110, intersected
the Director Vein structure at 73 metres from surface and below Trench No. 2.
Drill hole DS-13-112, drilled below DS-13-111, intersected the Director Vein
structure at 117 metres from surface and below Trench No. 2. Drill hole
DS-13-136, drilled below DS-13-112, intersected the Director Vein structure at
154 metres vertically from surface and below Trench No. 2. A second vein was
intersected on the hanging wall side of the Director structure and was located
about 150 metres vertically from surface. The four drill holes completed at this
location indicate that the structure maintains a relatively uniform width with
depth although the grade indicates a slight overall decrease with depth. The
results of the drilling under Trench No. 2 are similar to the information from
the previously reported results from Trench No. 3 area to the south and
indicates that the structure continues to be mineralized both along strike and
with depth. Parallel veins such as the vein identified in the hanging wall in
drill hole DS-13-136 have been known to develop into mineable veins in other
locations in the St. Lawrence area. The significance of this hanging wall vein
remains to be evaluated.


The following table details the results of the fifth set of drill holes
completed by CFI on the Director Vein Phase 1 and Phase 2 2013 diamond drill
program:




2013 Diamond-Drill Hole Assay Results                                       
                                                                            
Canada Fluorspar Inc.                                                       
St. Lawrence Project, NL                                                    
                                                                            
----------------------------------------------------------------------------
Drill hole DS-13-110                                                        
----------------------------------------------------------------------------
Sample No.             From (m)         To (m)     Length (m)         % CaF2
----------------------------------------------------------------------------
65261                     44.23          45.17           0.94          90.48
----------------------------------------------------------------------------
65262                     45.17          46.11           0.94          82.19
----------------------------------------------------------------------------
65263                     46.11          46.75           0.64          47.79
----------------------------------------------------------------------------
65264                     46.75          47.40           0.65          24.30
----------------------------------------------------------------------------

----------------------------------------------------------------------------
Drill hole DS-13-111                                                        
----------------------------------------------------------------------------
Sample No.             From (m)         To (m)     Length (m)         % CaF2
----------------------------------------------------------------------------
65271                     79.80          80.78           0.98          89.61
----------------------------------------------------------------------------
65272                     80.78          81.35           0.57          97.30
----------------------------------------------------------------------------
65273                     81.35          82.22           0.87          89.30
----------------------------------------------------------------------------
                                                                            
----------------------------------------------------------------------------
Drill hole DS-13-112                                                        
----------------------------------------------------------------------------
Sample No.             From (m)         To (m)     Length (m)         % CaF2
----------------------------------------------------------------------------
65303                    135.77         136.55           0.78          49.80
----------------------------------------------------------------------------
65304                    136.55         137.00           0.45          56.56
----------------------------------------------------------------------------
65306                    137.00         137.90           0.90          40.21
----------------------------------------------------------------------------
65307                    137.90         138.72           0.82          32.11
----------------------------------------------------------------------------
                                                                            
----------------------------------------------------------------------------
Drill hole DS-13-136                                                        
----------------------------------------------------------------------------
Sample No.             From (m)         To (m)     Length (m)         % CaF2
----------------------------------------------------------------------------
Vein #1                                                                     
----------------------------------------------------------------------------
65312                    207.80         208.50           0.70          81.27
----------------------------------------------------------------------------
                                                                            
----------------------------------------------------------------------------
Vein #2                                                                     
----------------------------------------------------------------------------
65392                    216.50         217.50           1.00          38.59
----------------------------------------------------------------------------
65313                    217.50         218.50           1.00          30.06
----------------------------------------------------------------------------
65314                    218.50         219.00           0.50          59.94
----------------------------------------------------------------------------
65315                    219.00         220.00           1.00          48.90
----------------------------------------------------------------------------
65316                    220.00         223.00           1.00          31.18
----------------------------------------------------------------------------
65317                    223.00         224.00           1.00          31.33
----------------------------------------------------------------------------
65318                    224.00         224.66           0.66          26.70
----------------------------------------------------------------------------



Assays on these drill holes were carried out at SGS Lakefield Laboratories
("SGS") of Lakefield, Ontario, using the Ion Selective Electrode method to
determine the fluorite content in the low-grade samples and the Dual Calcium
method for samples expected to contain high-grade values (i.e., those with
significant visible fluorspar in the drill core).


Quality Assurance and Quality Control ("QA/QC")

Check assay work by CFI includes insertion of duplicate samples and blanks with
regular batches of mineralized samples of drill core. QA/QC work is also done at
SGS, and results are reviewed and verified by CFI personnel. An independent
geological consultant (Qualified Person) has submitted additional samples
collected from the drill core for analyses.


Phase 1 of the current exploration program is designed to assess the northern
extension of the Director Vein structure. The six drill holes with assay results
to date have shown that the fluorspar mineralization at the Director Vein
extends further along strike and at depth from the old Alcan workings.


Phase 2 of the 2013 exploration program has been designed to evaluate the
southern extension of the Director Vein. A trenching program and a geophysical
survey conducted in the area during 2012 identified the structure over a strike
length of 1,000 metres. The current drill program was planned to evaluate the
mineral potential, at depth, of the southern extension of Director Structure and
to test the north extension of the adjacent Hares Ears Vein to the west.


Historic mining operations by Alcan on the property produced in excess of 4.2
million tonnes of fluorspar during a 44 year continuous production from 1942 to
1977. Production resumed in 1986 and continued until 1991, when St. Lawrence
Fluorspar Limited reopened the nearby Blue Beach North Mine and processed
440,000 tonnes of fluorspar ore from small open pits, one of which was located
in a surface pillar at the Director Mine near the main shaft.


Initial exploration information regarding the 2013 exploration program at
Director Vein was included in the Company's press releases dated January 16,
2013 and March 12, 2013.


To date, six (6) Phase 1 drill holes have been completed together with 26
additional drill holes in Phase 2 (19 holes in south extension Director Vein and
7 holes at Hares Ears Vein) of the 2013 exploration program. Assay results for
remaining completed drill holes in Phase 2 are pending.


Historic exploration data indicates that there are more than forty mineralized
veins within the CFI property. The three prominent vein structures, however, are
the Director Vein, Blue Beach North Vein, and the Tarefare Vein. Probable
Reserves of the Blue Beach North and Tarefare veins total approximately 5.4
million tonnes at an average grade of 39.8% CaF2. These Mineral Reserves have
been outlined to a vertical depth of 300 metres below the surface, but fluorspar
mineralization extends further at depth. The key assumptions, parameters and
methods used to estimate the Mineral Resources and Mineral Reserves, as well as
other relevant information, including data verification, with respect to the
Blue Beach North and Tarefare veins can be found in a NI 43-101 Technical Report
prepared by the Roscoe Postle Associates Inc. dated March 6, 2013, which has
been filed by the Company on SEDAR (www.sedar.com).


About the Company

The Company is a specialty mineral resource company engaged in the development
of fluorspar deposits located in St. Lawrence, Newfoundland, Canada, and is
reactivating the existing Blue Beach North and Tarefare underground fluorspar
mines, expanding the existing mill, constructing a new, environmentally-sound
Tailings Management Facility through Newspar, which it's a 50/50 joint venture
with Arkema. The Company is also building a new deep-water marine terminal in
the outer St. Lawrence Harbour for the export of fluorspar concentrate product.


Mr. James H. Reeves, Senior Geologist with CFI, who is a Qualified Person as
defined in National Instrument 43-101 - Standards of Disclosure for Mineral
Properties, reviewed and approved the technical content of this news release.
The information regarding historic production has not been verified by the
Company and is provided for reference only.


Material results of the Company's 2012 and 2013 exploration program have been
disclosed in the Company's press releases dated March 1, 13 and 30, 2012, April
16 and 24, 2012 and January 16, 2013, March 12, 2013, April 24, 2013, May 8,
2013, and June 5, 2013.


Neither TSX Venture Exchange nor its Regulation Services Provider (as that term
is defined in the policies of the TSX Venture Exchange) accepts responsibility
for the adequacy or accuracy of this release.


Cautionary Note and Forward-Looking Statements

This press release contains forward-looking statements which include, but are
not limited to: resource estimates, proposed mining techniques required to
construct and produce at expected levels, anticipated timing for completion of
metallurgical testing, the commencement of the drilling program, current
development and operating objectives and outlook, expectations, opinions,
forecasts, projections, guidance or other statements that are not statements of
fact. Although the Company believes that the expectations reflected in such
forward-looking statements are reasonable, it cannot give any assurance that
such expectations will prove to be correct. Results of the Company may be
affected by a variety of variables and risks associated with mining development
including: loss of market, volatility of commodity prices, currency
fluctuations, imprecision of reserve estimates, environmental risks, competition
from other producers, ability to access sufficient debt and equity capital from
internal and external sources, ability to generate sufficient cash flow to meet
its current and future obligations, regulatory approvals affecting construction
and mining operations. Such forward-looking statements are also based on a
number of assumptions which may prove to be incorrect, including, but not
limited to, assumptions about the following: the availability of financing for
exploration and development activities, the estimated timeline for the
development of the project at St. Lawrence, the supply and demand for, and the
level and volatility of the price of fluorspar, the assumptions on which
resource estimates are based, the receipt of necessary permit, market
competition, ongoing relations with employees and impacted communities, and
general business and economic conditions. Should one or more of the risks or
uncertainties involved in forward-looking statements materialize, or should the
assumptions prove incorrect, actual results may vary materially from those
anticipated, believed, estimated or expected. Accordingly, readers should not
place undue reliance on forward-looking statements.


Forward-looking statements are qualified entirely by this cautionary statement
and are given only as at the date of this press release. The Company disclaims
any obligation to update or revise any forward looking statements, whether as a
result of new information, future events or otherwise, except as required by
law.



FOR FURTHER INFORMATION PLEASE CONTACT: 
Canada Fluorspar Inc.
Lindsay Gorrill
President and CEO
1-800-823-8095
lgorrill@canadafluorspar.com